Scanning electron microscope (SEM) is a key tool for modern scientific exploration of the microscopic world. It plays an irreplaceable role in scientific research and industrial applications by enabling us to gain insights into the microscopic structure of matter through high-resolution electronic imaging technology. SEM scans the surface of the sample with a high-energy electron beam to collect s...
Read More
The major limitations on TEM performance are spherical aberration (also known as aberration), chromatic aberration, and astigmatism. The spherical aberration and chromatic aberration limit the resolution of traditional TEM. Both of these defects are inevitable when using static rotational symmetric electromagnetic fields. Ball aberration is the most important factor determining the performance of ...
Read More
In transmission electron microscopy (TEM) analysis, the primary and crucial step in obtaining a high-quality image that can be interpreted reasonably is sample preparation. Inappropriate sample thickness, poor conductivity, or damage introduced during sample preparation can directly lead to abnormal electron beam penetration, image distortion, and even sample scrapping. TEM sample requirements ① T...
Read More
Powder surface modification changes the surface state of particles through physical or chemical means, with the core being to break the agglomeration force between particles. When the particle size of the powder decreases to the micrometer or nanometer level, the surface energy sharply increases, and van der Waals forces, hydrogen bonds, and other gravitational forces cause the particles to sponta...
Read More
The preparation of nanopowders is generally categorized into Physical Methods and Chemical Methods. Below is a detailed comparison list highlighting their characteristics: Comparison Table: Physical vs. Chemical Synthesis of Nanopowders Feature Physical Methods (Top-down) Chemical Methods (Bottom-up) Basic Principle Top-down: Bulk materials are broken down into nanoparticles using p...
Read More
Scope: determination of Fe content/purity and impurity elements (Na, K, Ca, Mg, Al, Si, Mn, Cu, Pb, Cd, Cr, Ni, Zn, As, etc.) Instrumentation: ICP-OES (major Fe + common impurities, ppm level) / ICP-MS (trace impurities, ppb level) 1. Method Overview ICP-OES (Inductively Coupled Plasma – Optical Emission Spectrometry): major Fe content + common impurities (0.001%–100%), fast and cost-effective ICP...
Read More
What Size Do XRD, SEM and TEM Actually Measure? X-ray diffraction (XRD) records how a crystal scatters X-rays, conventionally with the diffraction angle 2θ on the horizontal axis and diffracted intensity on the vertical axis. A periodic arrangement of atoms produces diffraction peaks, and the width of a peak is related to the distance over which that arrangement remains coherent. The coherent doma...
Read More