Equipment

Home Equipment

O-3000 oxygen analyzer

new products

Latest News

February 2,2026.

SAT NANO Company's 2026 Spring Festival Holiday Notice

Dear all SAT NANO employees: On the occasion of the 2026 year Spring Festival, the company would like to extend its greetings and best wishes to you! Thank you for your efforts and contributions to the company over the past year. In order to reunite ...

January 8,2026.

New method for producing carbon nanotubes, increasing yield by 8 times

Against the backdrop of accelerated transformation of the global energy structure and synchronous growth in demand for advanced materials, how to achieve large-scale preparation of high value-added materials while reducing carbon emissions is becomin...

December 18,2025.

The penetration rate of new energy vehicles is rising, and the demand for spherical alumina is increasing

Under the wave of global electrification of automobiles, mainstream domestic and foreign car companies have increased their strategic layout of new energy vehicles, and new energy vehicles have entered a market driven high-speed growth period. The ne...

November 27,2025.

The spring of boron nitride thermal conductive materials is not far away

As one of the many thermal conductive materials, boron nitride is a unique one. Among the high thermal conductivity categories, it has high insulation, and among the high thermal conductivity and high insulation types, it is the cheapest. In the semi...

November 14,2025.

Small particle size and high energy: advantages and disadvantages of lithium battery materials

In the explosive growth of new energy vehicles, energy storage power stations, consumer electronics and other fields, the "heart" of lithium batteries - the particle size of active materials - is becoming the core password that determines battery per...

October 22,2025.

Market status and applications of single-walled carbon nanotubes

1、 Industry Status: Moving from Laboratories to Large Scale and Mass Production As the "super graphene" in the carbon material family, single-walled carbon nanotubes (SWCNTs) are widely used in cutting-edge fields such as lithium battery conductive a...

September 22,2025.

Carbon nanotubes have achieved important another new breakthrough

With the development of integrated circuit (IC) technology, the scaling of silicon-based metal oxide semiconductor (MOS) field-effect transistors (FETs) is approaching their fundamental physical limits. Carbon nanotubes (CNTs) are considered promisin...

September 17,2025.

Patent release of ferrite magnetic powder materials

In recent years, with the continuous development and popularization of wireless communication technology, the application scenarios of wireless communication have become increasingly widespread, such as mobile phone communication, wireless data trans...

August 13,2025.

Can silver coated copper powder replace silver powder to promote cost reduction and efficiency improvement in the photovoltaic industry

Currently, the photovoltaic industry is accelerating its iteration towards efficient N-type battery technology, and heterojunction (HJT) cells have become a highly promising development direction due to their outstanding advantages such as high conve...

August 7,2025.

Carbon nanotube powder breakthrough, approaching limit

Carbon nanotubes powder, as one of the strongest structural materials in theory, can achieve mechanical properties of hundreds of GPa level strength and TPa level modulus per single strand. However, the realization of such outstanding performance in ...

O-3000 oxygen analyzer

August 22,2018.

Instrument Description: It can quickly and accurately measure the oxygen content in steel, rare earth materials, alloys, copper, zirconium, titanium, ceramics, powder materials and other inorganic materials. The instrument has the advantages of high sensitivity, good performance, wide measuring range and accurate and reliable analysis results.

1. Reliable sample extraction unit
Pulse furnace power control heating (0-8KVA), the maximum temperature can reach 3000 °C.
A variety of programming methods: constant power temperature rise, slope temperature rise.
A variety of choices of crucible design: for different sample release, in addition to the standard crucible,
2. Oxygen analysis using non-dispersive infrared detection system
3. Modular detection unit
Infrared detection unit: standard configuration Oxygen and nitrogen analyzer is equipped with two independent infrared absorption cells, which can flexibly configure the length of the absorption pool and the number of channels according to user requirements.
Detector: using German imported pyroelectric solid-state infrared CO2 detector
Motor: Swiss imported synchronous motor, continuous operation without failure
Light source: It adopts infrared light source imported from the United States, which is not easy to oxidize and has stable optical performance.
Constant temperature: The entire chamber is thermostatically controlled to ensure constant temperature of the analytical gas and ensure measurement accuracy;
Protective gas: The infrared light source and detector use nitrogen protection and purification to isolate the influence of the surrounding environment and improve stability and measurement accuracy.
Instrument parameters:
1. Analysis range
Oxygen: low oxygen: 0.0001% to 0.5% hyperoxia: 0.5% to 20%
Note: Changing the sample size can change the measurement range.
2. Analysis accuracy: 1ppm or 1%
Note: It is not more than the standard deviation or uncertainty of the sample.
3. Sensitivity: 0.01ppm

Leave a message Please click here for inquiry
Provide the right solution according to your needs,offer efficient service,leave a message for the product information and requirements you need,customize now!